  • If the assigned exposure time is 80 ms, the actual time must be within which range?
  • Which combination of object-to-image distance (OID) and source-to-image distance (SID) would produce the highest spatial resolution?
  • How does decreased image contrast affect the structural sharpness of a radiograph?
  • In radiographic imaging of the chest, which pathology is most likely to increase subject contrast?
  • A technologist is using a variable kilovoltage peak (kVp) chart to set the exposure technique for a table-top radiograph. If the technique chart calls for 76 kVp but the technologist uses 140 kVp, the resulting image will likely demonstrate which of the following?
  • What does AEC stand for in radiography?
  • Which statement correctly describes the relationship between object-to-image distance (OID) and magnification?
  • Which statement about source-to-image distance (SID) and size distortion is correct?
  • GSDF calibration primarily ensures consistent grayscale rendering across displays, which most directly affects which image attribute?
  • In focal spot blur calculations, SOD stands for which distance?
  • In digital imaging, the DICOM grayscale standard display function (GSDF) relates to which aspect of image display?
  • What pathology is indicated by increased opacity in the right lower lobe and loss of subject contrast?
  • High contrast is defined by:
  • A radiographic histogram is used to illustrate which of the following?
  • Which situation will result in the greatest amount of shape distortion?
  • Remnant beam is best described as which of the following?
  • Which grid ratio yields the highest image contrast given the same exposure conditions?
  • To reduce receptor exposure for a portable chest radiograph when technique cannot be increased, which action should be taken?
  • Exposure of a small lead block is a technique used to evaluate which of the following?
  • A forearm radiograph is acquired using 2 mA at 60 kVp. Which kVp is approximately required to double the exposure?
  • 1 millisievert is equal to which value in sieverts?
  • Which factor most directly influences the display monitor spatial resolution in a digital radiography system?
  • Which combination yields the maximum spatial resolution?
  • What is the relationship between technical factors and the S-number indicator used on some computed radiography (CR) equipment?
  • Which of the following angles are not considered part of beam geometry?
  • If a radiograph demonstrates an "S" (sensitivity) number of 80 with no visible exposure errors, the technologist should consider which action?
  • With the source-to-image distance (SID) of 80 cm (31 inches), the actual central ray must be within what distance of the indicated image field center?
  • When the matrix size of a digital image decreases, what happens to the number of pixels?
  • Which skull projection would result in elongation of the anatomy being imaged?
  • A radiographic histogram is a graphic representation of which concept?
  • Which statement about detector element size and image sharpness is true?
  • Routine image calibration ensures that the image receptor maintains an accurate and reliable:
  • In QC testing, receptor exposure is commonly measured in which unit?
  • The actual exposure time must be accurate within what range when the assigned exposure time is 100 milliseconds (ms)?
  • Which measurement represents the smallest object-to-image distance (OID) among the options?
  • Which statement about how SID affects size distortion is correct?
  • DICOM PS3.14 is a standard that controls which of the following?
  • Which quality assurance parameter is primarily concerned with achieving the same image exposure across repeated radiographs?
  • Which of the following statements best describes a typical action when an S-number indicates no exposure errors in DR imaging?
  • Which distance is measured from the focal spot to the image receptor?
  • What is the distance between the anatomy being imaged and the focal spot called?
  • Why is validating SID accuracy important in radiography QA?
  • A blank image receptor shows an area with lower radiation response. This may be a problem with which property?
  • What is the primary factor controlling subject contrast?
  • Which standard maps luminance across displays for radiography quality control?
  • Actual exposure time must be within what percentage of the indicated exposure time?
  • Which term describes the processing operation that increases image contrast using a lookup table (LUT)?
  • GSDF stands for which term?
  • True or False: The potential benefits of exposing patients to ionizing radiation should far outweigh any slight chance of inducing radiogenic malignancy or genetic defects.
  • If the assigned exposure time is 72 ms, the actual exposure time must be accurate within which range?
  • In quality control, the maximum allowed variation in x-ray tube output for identical settings is which percentage?
  • Which factor has the greatest influence on radiographic image contrast?
  • Which of the following information is required to be included in Digital Imaging and Communications in Medicine (DICOM) images?
  • How is source-to-object distance calculated?
  • Spatial resolution is measured in which unit?
  • Which of the following DEL sizes would provide the highest spatial resolution?
  • Which formula is used to determine the magnification factor?
  • To improve spatial resolution, which action should a technologist take?
  • What is the primary purpose of using a grid in radiography?
  • Which QA test verifies the alignment between the radiographic field and the light field?
  • Which image processing factor influences radiographic image contrast?
  • Which factor can cause a region of decreased exposure across the plate after processing?
  • Subject contrast in radiography refers to which of the following?
  • Elongation occurs as a distortion when there is angulation of the object relative to the image receptor. Which of the following lists the correct related distortion?
  • What is the most likely adverse effect of processing a radiographic image under the wrong anatomic part?
  • How many shades of gray can one monitor pixel display at a time?
  • Which of the following identifiers are required by law to be included on a radiographic image?
  • In an automatic exposure control (AEC) test, if an exposure through 10 cm of aluminum results in a receptor exposure of 100 microgray, an exposure through 5 cm of aluminum should result in receptor exposure in which of the following?
  • Which term describes a computer processing feature that influences radiographic image contrast?
  • Which object-to-image distance (OID) would cause the greatest amount of penumbra?
  • If a requisition calls for a two-view knee radiograph but the technologist performed a two-view tibia-fibula series, how should this be corrected?
  • An x-ray system with unreliable exposure reproducibility may result in which adverse effect?
  • If the matrix size decreases, the number of pixels within the image will what?
  • In digital radiography, how is patient information embedded into the image?
  • The irregular deviation index (DI) for a detector indicates a quality control issue related to which?
  • Define the term radiation protection.
  • Which quality control parameter directly influences the consistency of image contrast across a monitor?
  • Which of the following is NOT a beam geometry factor?
  • In digital radiography, what is the effect of increasing matrix size on spatial resolution?
  • Long gray-scale is synonymous with:
  • What is the effect of an air-filled bowel obstruction on abdominal subject contrast?
  • What term refers to a single detector element in a digital radiography receptor?
  • An under-exposed radiographic image may exhibit which artifact?
  • The spatial resolution of a radiographic system is measured in units of
  • Which display adjustment directly controls the range of grayscale values displayed on a monitor?
  • How often should technologists check the exposure indicators and deviation index on a radiograph?
  • Which change to exposure geometry would most effectively reduce receptor exposure for a portable chest exam when dose must be kept low?
  • To increase spatial resolution, which detector element (DEL) characteristic should be decreased?
  • Increased kilovoltage peak (kVp) affects differential attenuation of the x-ray beam by:
  • Which is a post-processing factor that affects the displayed image contrast?
  • An AP chest radiograph was obtained with 40 inches SID, 14x17 field size, 2.5 mm Al filtration, and a 12:1 grid. Which change would increase receptor exposure?
  • Which term best describes the process of adding brightness and contrast to exposure values within a radiographic image?
  • How many pixels are in a 2 MP monitor?
  • A lateral knee radiograph shows the femoral condyle overlapped with the joint space. Which adjustment will correct this error?
  • The displayed SID should match the actual SID within what tolerance?
  • Patient motion on a radiograph will have what type of appearance?
  • Which of the following is NOT a factor affecting receptor exposure?
  • Which tissue yields the highest signal intensity at the image receptor?
  • Which technical factor should the technologist use to control the receptor exposure?
  • When the selected tube voltage is 80 kilovoltage peak (kVp), the actual kVp must be accurate within a range of which of the following?
  • Which term describes the edge blur at the boundary of an object on a radiographic image?
  • Which statement about Detector Elements (DELs) is NOT true?
  • To correct a knee lateral view where the condyle overlies the joint space due to misalignment, which parameter should be adjusted?
  • Gray-scale is defined as which of the following?
  • When the SID is 40 inches (102 cm), the actual SID should match the displayed SID within a range of:
  • How does increasing window width affect the displayed image?
  • Which description best matches low-contrast radiographic images?
  • Which statement best aligns with the concept of 'values of interest' in radiographic exposure processing?
  • Exposure linearity between adjacent mA stations must be within what tolerance?
  • Large signal differences in the remnant beam produce an image with which characteristic?
  • Which testing evaluates the accuracy of the light field relative to the radiographic field?
  • A non-uniform image receptor (IR) will demonstrate which of the following?
  • An increase in object-to-image distance (OID) will result in which change to image sharpness?
  • What term describes the grainy appearance due to insufficient exposure data in digital radiography?
  • Saturation artifact on a radiograph is caused by which exposure condition?
  • What does SID stand for in radiography?
  • In ensuring patient safety, which action would be inappropriate and should be avoided?
  • Changes to milliamperage (mA) or exposure time affect which aspect of the X-ray beam?
  • Which of the following variables affecting receptor exposure can be controlled by the X-ray operator?
  • On a radiographic histogram, the highest exposure readings typically correspond to which scenario?
  • To reduce magnification, which distance parameter should be decreased?
  • Which of the following variables, when increased, is associated with increased spatial resolution?
  • Which adjustment would increase image contrast on a radiograph?
  • Which value represents the highest level of structural sharpness among the given options?
  • Which metric is used to quantify the deviation of the actual exposure from the expected exposure on a radiograph?
  • In radiographic imaging, which unit is used to quantify spatial resolution?
  • To reduce foreshortening of the femoral neck on an AP hip image, which action is recommended?
  • Increasing the source-to-image distance (SID) has what effect on receptor exposure?
  • Which concept describes the ability to distinguish closely spaced structures in an image?
  • What does the acronym SID stand for?
  • If the assigned exposure time is 60 ms, the actual exposure time should be no more than which value?
  • How does an increased grid ratio affect radiographic image contrast?
  • What does ALARA stand for?
  • What is the SI subunit of measure for absorbed dose?
  • Which anatomical feature is commonly used as an indicator of spatial resolution in radiographic images?
  • What term describes the component of digital radiography receptors responsible for capturing the radiation signal transmitted through the patient?
  • Which statement is true regarding aluminum filtration and receptor exposure?
  • Plate uniformity testing in computed radiography checks for which property?
  • Receptor exposure is defined as the amount of radiation striking the image receptor.
  • Blurring at the edges of an object on a radiograph is referred to as what?
  • Which of the following anatomical parts can be an indicator of the spatial resolution recorded in the radiographic image?
  • A patient has a nail protruding from the plantar surface of the foot, creating an unavoidable large OID on an AP foot radiograph. To minimize magnification, what should the technologist do?
  • What term describes the light-emitting components within display monitors?
  • What is the primary disadvantage of using a high-ratio grid?
  • Which of the following is NOT a primary contributor to shape distortion due to misalignment?
  • In digital radiography, which exposure outcome is typically associated with saturation on a detector?
  • Increasing aluminum filtration from 3.0 to 3.5 mm Al would result in which one of the following changes to receptor exposure?
  • If a radiograph exposure is produced with 4 mAs at a certain kVp resulting in a receptor exposure of 0.001 mGy, what receptor exposure would result if mAs is increased to 8 with the same kVp?
  • In digital radiography quality control, the Deviation Index (DI) values across detectors are used to indicate issues primarily with which subsystem?
  • Which distance measurement is associated with penumbra increase in radiographic imaging?
  • Which statement best characterizes an image with long gray-scale and many shades of gray?
  • Which statement about filtration is correct?
  • Which statement describes the effect of increasing window width on image contrast?
  • The actual kilovoltage peak (kVp) of an exposure must correspond to the selected kVp within what percentage?
  • In digital imaging, what does the term PIXEL represent?
  • Shape distortion includes which of the following types?
  • When reviewing a radiographic exposure indicator, a sensitivity number significantly below 200 indicates what about receptor exposure?
  • What is the magnification factor when a 42-inch source-to-image distance is used and there is an object-to-image distance of 10 inches?
  • A test pattern of line-pair combinations displayed on a PACS monitor evaluates which aspect of the display?
  • How does ascites affect the subject contrast of the abdomen?
  • The central ray indicator must align to the actual center of the x-ray field within what tolerance?
  • Decreasing kilovoltage peak (kVp) affects differences in signal intensity in the remnant beam by:
  • Which distance is measured from the focal spot to the object?
  • During QC, the variation in tube output for identical technique parameters should not exceed what percentage?
  • Which of the following is an exposure parameter rather than a beam geometry parameter?
  • The milligray/milliampere-seconds (mGy/mAs) measurement between adjacent mA stations should not vary by more than:
  • Increasing the object-to-image distance (OID) while the source-to-image distance (SID) remains constant will cause focal spot blur to do what?
  • What must imaging facilities have that provides for patient protection and patient education?
  • Which statement correctly describes the relationship between kilovoltage peak (kVp) and differential attenuation?
  • An exposure at 70 kVp and 10 mAs produces a beam intensity of 341 microgray. Calculate Gy/mAs.
  • Processing a radiographic image using the wrong histogram protocol may result in visible errors such as which of the following?
  • Which statement best expresses the practical application of ALARA in radiographic procedures?
  • To decrease receptor exposure in a portable chest radiograph when the technique is limited, which action is most appropriate?
  • In digital radiography imaging, what does DEL stand for?
  • In an automatic exposure control (AEC) test, if exposure through 1 centimeter of aluminum results in a receptor exposure of 10 microgray, exposure through 2 cm of aluminum should result in receptor exposure of which?
  • Using a variable kilovoltage peak (kVp) chart, if the chart calls for 87 kVp but 82 kVp is used, the resulting image will likely show which outcome?
  • Which of the following identifiers is required by law to be included on a radiographic image?
  • Which exposure time is outside acceptable limits when the console is set to 300 milliseconds (ms)?
  • With a source-to-image distance (SID) of 80 cm, the light field should match the exposure field within which range?
  • Which image processing parameter is commonly used to adjust the displayed brightness and contrast after acquisition?
  • At a source-to-image distance (SID) of 60 inches (152 cm), the central ray must align to the central ray indicator within:
  • What SID value is described as the standard starting point in the examples?
  • An image produced with excessively high mAs can be identified based on which indicator?
  • Which option presents a correct set of factors that affect spatial resolution in digital radiography?
  • Which technologist mistake is most likely to cause processing errors within a computed radiography (CR) system?
  • Detector Elements (DELs) influence which aspect of image quality most directly?
  • When the anatomy is parallel to the image receptor and the X-ray beam is angled, what type of distortion occurs?
  • Which statement correctly describes the relationship between SID and size distortion?
  • Which projection would result in foreshortening of the anatomy being imaged?
  • Which option would most directly increase spatial resolution?
  • Failing to adjust exposure factors for a patient with severe osteoporosis would most likely cause which effect on receptor exposure?
  • A decrease in SID primarily increases which aspect of the image?
  • Which item is legally required to appear on a radiographic image to document the examination?
  • Which artifact is produced when a CR image receptor is not completely erased before the next use?
  • What term describes a body section that produces a remnant beam with widely varying signal intensities?
  • If the technique chart calls for 12 mAs but the technologist uses 1.5 mAs on a portable radiograph, the resulting image will likely demonstrate which of the following?
  • Which technique converts a measured radiographic histogram to the expected histogram by applying a transfer function?
  • How can a technologist correct an image of an anteroposterior (AP) hip that demonstrates foreshortening of the femoral neck?
  • For SID 80 cm, the light field should match the exposure field within +/- 2% of SID. What is this distance in centimeters?
  • Which image quality factor is defined as the structural sharpness recorded in the radiographic image?
  • The largest difference in signal intensities within the remnant beam of a chest exposure describes which property?
  • The SID indicator must represent the actual SID within what tolerance?
  • Which matrix size is associated with the highest spatial resolution?
  • If a technologist exposes a radiograph with the wrong patient name, what is the proper corrective action?
  • Which statement about Detector Elements (DELs) is NOT true?
  • Which factor is considered the most important for influencing the contrast of a radiographic image?
  • Increasing subject contrast increases the visibility of anatomy and pathology due to which of the following?
  • Line-pairs per millimeter (lp/mm) are used to assess which aspect of image quality?
  • A technologist observes that images viewed on one PACS monitor demonstrate lower contrast than others. This monitor is demonstrating an error related to which of the following?
  • Non-conformity to the DICOM PS3.14 standard may result in which effect?
  • Which option is not considered part of beam geometry angles in radiography?
  • Which piece of information must be physically included on an x-ray image to verify laterality?
  • During QC testing of a CR system, a receptor demonstrates weaker radiation response on one side. This issue is related to which?
  • Which component is most directly used to map raw pixel values to displayed shades of gray?
  • What is the process called that identifies the values of interest in a radiographic histogram?
  • For an SID of 80 cm, the acceptable actual SID range is:
  • Which focal spot size yields the highest spatial resolution?
  • Which of the following is NOT a factor that affects spatial resolution in digital radiography (DR)?
  • What is the effect of increasing source-to-image distance (SID) on receptor exposure?
  • What is the recommended practice for monitoring exposure indicators during a radiographic series?
  • Which of the following is used to create the patient's requisition?
  • According to the inverse square law, doubling the SID results in receptor exposure changes of approximately:
  • When reviewing the radiographic exposure indicator, when does an 'S' (sensitivity) number significantly above 200 indicate?
  • A radiograph is acquired using an automatic exposure control unit with an exposure setting of 200 mA and 100 kVp. If the initial receptor exposure is measured as 50 microgray, increasing the technique to 300 mA will result in a receptor exposure of which value?
  • The light field must correspond to the actual exposure field within a tolerance of:
  • A QC test with beam intensity measured 300 microgray at 100 kVp and 10 mAs. A second exposure with the same technique should match within what tolerance?
  • Which exposure reading is processed as a part of the "values of interest" within a radiographic image?
  • Which factor is most relevant to preventing non-uniform response across an imaging plate?
  • Incomplete erasure of a CR image receptor may produce an artifact called:
  • Which of the following can also be referred to as size distortion?
  • Low contrast is defined by:
  • What term (and acronym) is used to express the principle of keeping radiation exposure to a level that minimizes the potential for adverse biological damage to humans?
  • Which part of the x-ray beam has signal intensities that correspond to the anatomy represented on the image receptor?
  • Which type of shape distortion occurs when there is angulation of the image receptor?
  • Increasing filtration has what effect on receptor exposure?
  • Which of the following describes the factors of the image receptor that influence spatial resolution?
  • Which equation correctly expresses the source-to-object distance (SOD) in terms of SID and OID?
  • An image is acquired with a 2 mm focal spot, 5 cm object-to-image distance (OID), and 102 cm source-to-image distance (SID). What is the resulting focal spot blur?
  • Which artifact or processing outcome is most likely if histogram processing is done incorrectly, leading to suboptimal image brightness and contrast?
  • When can a technologist reuse the computed radiography (CR) receptor after the appearance of a ghost image?
  • What monitor size is recommended by the American College of Radiography (ACR) for routine radiography?
  • The x-ray tube output for identical technical parameters should not vary by more than what percentage?
  • Which of the following best describes the purpose of a radiographic histogram analysis?
  • If object-to-image distance increases while SID remains constant, magnification will:
  • On some CR systems, the S-number indicator is influenced by which of the following factors?
  • Which statement accurately describes a radiographic histogram?
  • Which of the following statements describes the effect of receptor exposure on image quality?
  • Grayscale calibration primarily affects which aspect of monitor performance?
  • A radiographic histogram is defined as which of the following?
  • Which factor causes quantum mottle on a radiograph?
  • What is the purpose of a Look-up Table (LUT) in monitor display handling?
  • To improve spatial resolution and visualize important anatomical aspects, such as fractures, which DEL size is preferred?
  • On a portable chest radiograph of a very small patient, the receptor exposure is higher than desired even with low mAs and kVp. How can the technologist decrease receptor exposure?
  • Which option might make it difficult to visualize the anatomy and pathology of the abdomen?
  • When the matrix size increases, the size of the pixels within the image:
  • What is used to test a monitor's spatial resolution?
  • Each PACS monitor must be calibrated to GSDF to ensure images are displayed with correct:
  • Which finding on a histogram indicates excessive receptor exposure?
  • X-ray systems must demonstrate exposure reproducibility within what tolerance?
  • If a chest radiograph has been processed under the abdomen histogram protocol, what is the correct remediation?
  • In radiographic post-processing, which method maps input exposure values to a new brightness level using a stored table?
  • What process converts the original radiographic histogram to the expected histogram?
  • When the matrix size of a digital image decreases, the size of the pixels within the image:
  • Which description best defines gray-scale in radiography?
  • What important image quality factor is described as the structural sharpness recorded in the radiographic image?
  • Distended loops of air-filled bowel and increased subject contrast throughout the abdomen indicate which pathology?
  • Who should justify the need for every radiation procedure and accept responsibility for protecting the patient from unnecessary radiation exposure?
  • Physical damage to the structure of a computed radiography (CR) image receptor is most likely to manifest on a radiograph as which artifact?
  • Which combination yields the highest spatial resolution?
  • Which magnification factor would result in the greatest amount of size distortion present on an image?
  • The lowest exposure readings on a radiographic histogram usually represent areas of which exposure?
  • A chest radiograph shows low contrast. Which post-processing adjustment might be used to increase the contrast?
  • A dead detector element (DEL) is visible within a radiograph of the orbits performed for MRI screening. This error should be corrected by:
  • Spatial resolution in digital radiography is defined as
  • Which factors influence penumbra in radiographic imaging?
  • Detector element (DEL) pitch refers to which physical dimension?
  • Which monitor calibration setting is most directly involved in ensuring consistent brightness across the display?
  • What term describes the smallest unit of information within a digital image?
  • Image contrast is defined as the visible difference in:
  • A diagnostic x-ray system must demonstrate exposure linearity within an error margin of what percentage?
  • When the digital image matrix size increases, what happens to the size of the individual pixels?
  • Which of the following is equivalent to size distortion in radiography?
  • Which scenario would most likely improve image sharpness by geometry, assuming constant SID and OID?
  • Which processing step maps input pixel values to output to adjust image brightness and contrast?
  • If SID is 100 inches and OID is 20 inches, what is the source-to-object distance (SOD)?
  • An automatic exposure control radiograph is taken at 200 mA and 60 kVp. If initial receptor exposure is 20 microgray and kVp is increased to 69 while keeping other parameters, the receptor exposure will be which value?
  • If a technologist processes a chest radiograph with the abdomen histogram protocol, what corrective action should be taken?
  • Which combination would produce an image with the highest spatial resolution?
  • Which of the following items is most appropriate to include on a radiographic image to aid identification and interpretation?
  • Which term describes the signal differences in the remnant beam?
  • Which factor affects displayed image contrast during post-processing by altering the range of gray values?
  • Safeguards against unnecessary radiation exposure are based on which evidence?
  • PA clavicle projection increases spatial resolution because of which factor?
  • Which projection employs shape distortion to elongate anatomy for improved visualization?
  • Which parameter is most directly addressed by routine calibration to ensure repeatable radiographic outputs?
  • If the matrix size is doubled (FOV constant), pixel size will:
  • What primarily controls the display monitor spatial resolution?
  • Pixel malfunction within a digital radiography image receptor is likely to manifest on a radiograph as which artifact?
  • A radiographic image with an S value significantly above the normal range signals which issue?
  • A DEL artifact visible in a radiograph should be corrected by:
  • Increasing the kVp from 60 to 69 kVp with identical technique parameters yields receptor exposure of which value?
  • Large visible differences in brightness are defined as
  • What is the primary purpose of regularly testing and calibrating the central ray alignment?
  • Which description correctly identifies the display monitor's grayscale and brightness calibration?
  • Which body habitus would result in the largest object-to-image distance (OID) on an abdomen radiograph?
  • The highest quality radiograph would be produced by which combination of SID and OID?
  • Which artifact is most commonly linked to underexposure of the image?